Diagnosis Procedure
WARNING: This page is about a different car, the 2016 Nissan Murano. However, it is still accessible from the selected car via links, so may be relevant.
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL (PUSH-BUTTON IGNITION SWITCH)
- Disconnect push-button ignition switch connector.
- Check voltage between push-button ignition switch connector M208 terminal 8 and ground.
Push-Button Ignition Switch Ground Voltage
(Approx.)Connector Terminal M208 8 - Battery voltage
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
GO TO STEP 4 .
- CHECK IGNITION SWITCH OUTPUT SIGNAL (IPDM E/R)
Check voltage between IPDM E/R connector E119 terminal 38 and ground.
IPDM E/R Ground Voltage
(Approx.)Connector Terminal E119 38 - Battery voltage Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (IPDM E/R)
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector E119 and BCM connector M18.
- Check continuity between IPDM E/R connector E119 terminal 38 and push-button ignition switch connector M208 terminal 8.
IPDM E/R Push-Button Ignition Switch Continuity Connector Terminal Connector Terminal E119 38 M208 8 Yes - Check continuity between IPDM E/R connector E119 terminal 38 and ground.
IPDM E/R Ground Continuity Connector Terminal E119 38 - No
Is the inspection result normal?
YES
Refer to INTERMITTENT INCIDENT .
NO
Repair or replace harness or connectors.
- CHECK IGNITION SWITCH OUTPUT SIGNAL (BCM)
Check voltage between BCM connector M18 terminal 1 and ground.
BCM Ground Voltage
(Approx.)Connector Terminal M18 1 - Battery voltage Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION .
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (BCM)
- Turn ignition switch OFF.
- Disconnect BCM connector M18 and IPDM E/R connector E119.
- Check continuity between BCM connector M18 terminal 1 and push-button ignition switch connector M208 terminal 8.
BCM Push-Button Ignition Switch Continuity Connector Terminal Connector Terminal M18 1 M208 8 Yes - Check continuity between BCM connector M18 terminal 1 and ground.
BCM Ground Continuity Connector Terminal M18 1 - No
Is the inspection result normal?
YES
Refer to INTERMITTENT INCIDENT .
NO
Repair or replace harness or connectors.