Transmission Fluid Level Check
- Remove the engine room under cover front B assembly. (Refer to UNDER COVER .)
- Start the engine, and let it run at idle to warm it up for 15 minutes.
- Move the shift lever to every position (P, R, N, D, manual mode) (Hold for 20 seconds in each position), and then move it to the P range.
- Stop the engine.
- Remove the air cleaner element and air cleaner intake duct. (Refer to AIR CLEANER .)
- Remove the filler plug.CAUTION:
- The drained fluid can be reused if it is between the replacement intervals.
< Replacement interval>
- Normal condition: 96,000 km (60,000 miles)
- Severe condition: 48,000 km (30,000 miles)
- When reusing the drained fluid, make sure that no foreign object gets into the fluid.
- The drained fluid can be reused if it is between the replacement intervals.
- Remove the drain plugs, and leave it for 3 minutes to drain the fluid.NOTE: Because the fluid in the oil cooler, oil filter, and transaxle assembly cannot be drained, the amount of drained fluid will be approximately 5.5 dm3 (approximately 5.8 quarts).
- Tighten the drain plugs to the specified torque.
Tightening torque: 35 ± 5 N.m (26 ± 4 ft-lb)
CAUTION: Measure the drained fluid. If the drained fluid is less than approximately 5.5 dm3 (approximately 5.8 quarts), add new fluid to make it approximately 5.5 dm3 (approximately 5.8 quarts). - Fill the fluid into the filler plug.
Brand name: Dia Queen SSTF-I
Filling amount: Approximately 5.5 dm 3 (approximately 5.8 quarts)
- Tighten the filler plug to the specified torque.
Tightening torque: 35 ± 5 N.m (26 ± 4 ft-lb)
- Install the air cleaner element and air cleaner intake duct. (Refer to AIR CLEANER .)