Interior Light Test 2B - Courtesy Light Inoperative With Any Door
NOTE:
Perform INTERIOR LIGHT TEST 2A
before proceeding with this test. For connector terminal identification, refer to CONNECTOR IDENTIFICATION
For wiring diagrams, refer to WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
Disconnect probe from junction block 6-pin connector. Turn ignition off. Disconnect BCM from junction block and ensure connector is clean and not damaged. Using external voltmeter, measure voltage between ground and terminal No. 9 on junction block BCM connector. If voltage is more than 10 volts, replace BCM. If voltage is 10 volts or less, replace junction block.