Installing the control module
Center the control module to the hydraulic modulator valves before the valves are pushed into place.
- Install the control module. Tighten the screws. Tighten to 1.8 Nm.
Connect:
- The connectors for the pump motor and control module
- Remove the air cleaner (ACL) housing and the hose for air pre-heating.