Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Volkswagen >> 2000 >> Jetta GLX, Standard >> Repair and Diagnosis >> Engine Performance >> System >> 2.8L - Fuel Injection Ignition, Engine Code(S): AFP (A4 Platform) >> 28 Ignition/Glow plug system >> Ignition system, servicing >> Misfire recognition, checking >> Work sequence

Work sequence

Indicated on display

Rapid data transfer HELP
Select function XX

Indicated on display

Read Measuring Value Block
Input display group number XXX

Indicated on display: (1-4 = display fields)

Read Measuring Value Block 14 ->
1 2 3 4
  Display fields
  1 2 3 4
Display group 014: Ignition, misfire recognition
Display xxxx RPM xxx % xxx Activated Blocked
Indicated Engine speed (in 40 steps) Engine load Three Way Catalytic Converter (TWC) damaging misfires (total) Misfire recognition status
Working range 0-6800 RPM 0-100 % 0-65000 ---
Specified value 680-720 RPM greater than 14% 0 activated
  --- --- If the specified value is not obtained Evaluating display group 14,

If the specifications are obtained:

If the specified values are not attained:

Indicated on display: (1-4 = display fields)

Read Measuring Value Block 15 ->
1 2 3 4
  Display fields
  1 2 3 4
Display group 015: Ignition, misfire recognition
Display xxx xxx xxx Activated Blocked
Indicated Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 1 Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 2 Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 3 Misfire recognition status
Working range 0-65000 0-65000 0-65000 ---
Specified value 0 0 0 activated
  If the specification is not obtained , Evaluating display groups 15 and 16

If the specifications are obtained:

Indicated on display: (1 and 4 = display fields)

Read Measuring Value Block 16 ->
1 4
  Display fields
  1 2 3 4
Display group 016: Misfiring recognition
Display xxx xxx xxx Active Blocked
Indicated Exhaust damaging misfires Cyl. 4 Exhaust damaging misfires Cyl. 5 Exhaust damaging misfires Cyl. 6 Misfire status recognition
Working range 0-65000 0-65000 0-65000 ---
Specified value 0 0 0 activated
  If the specification is not obtained , Evaluating display groups 15 and 16