Inspection [06/2024 - ]: Procedure
- INSPECT NO. 2 AIR FUEL RATIO SENSOR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Air Fuel Ratio Sensor)Standard Resistance
Tester Connection Condition Specified Condition D13-1(HA1B) - D13-2(+B) 20°C (68°F) 2 to 6 Ω D13-1(HA1B) - D13-4(A1B-) Always 10 kΩ or higher - If the result is not as specified, replace the No. 2 air fuel ratio sensor.
- Measure the resistance according to the value(s) in the table below.