Inspection [12/2023 - ]: Procedure
- INSPECT AIR FUEL RATIO SENSOR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Air Fuel Ratio Sensor)Standard Resistance
Tester Connection Condition Specified Condition Result D24-1 (HA1A) - D24-2 (+B) 20°C (68°F) 1.4 to 3.0 Ω Ω D24-1 (HA1A) - D24-4 (A1A-) Always 10 kΩ or higher kΩ If the result is not as specified, replace the air fuel ratio sensor.
- Measure the resistance according to the value(s) in the table below.