Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch [11/2020 - 12/2023]: Procedure
- READ VALUE USING GTS (MASTER SWITCH)
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
Body Electrical > Master Switch > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- Body Electrical > Master Switch > Data List
Tester Display D Door P/W Auto SW OK
On the GTS screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
NG
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to REMOVAL [11/2020 - ]
Result:
OK
See step 2
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
- READ VALUE USING GTS (D-DOOR MOTOR)
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
Body Electrical > D-Door Motor > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- Body Electrical > D-Door Motor > Data List
Tester Display D Door P/W Auto SW OK
On the GTS screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
NG
See step 4
Result:
OK
See step 3
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
- PERFORM INITIALIZATION
- Initialize the front power window regulator motor assembly LH.
Refer to INITIALIZATION [11/2020 - 12/2023]
OK
Power window system operates normally.
Result
Proceed to OK NG
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [11/2020 - 11/2021] , or refer to REMOVAL [11/2021 - 12/2022] , or refer to REMOVAL [12/2022 - 12/2023]
- Initialize the front power window regulator motor assembly LH.
- REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
- Temporarily replace the multiplex network master switch assembly with a new or normally functioning one.
Refer to REMOVAL [11/2020 - ]
OK
Power window system operates normally.
Result
Proceed to NG OK
Result:
NG
END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
Result:
OK
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [11/2020 - 11/2021] , or refer to REMOVAL [11/2021 - 12/2022] , or refer to REMOVAL [12/2022 - 12/2023]
- Temporarily replace the multiplex network master switch assembly with a new or normally functioning one.