Inspection [11/2015 - ]: Procedure
- INSPECT CRANK POSITION SENSOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Cold 985 to 1600 Ω Hot 1265 to 1890 Ω HINT:
In the table above, the terms Cold and Hot refer to the temperature of the coils. Cold means approximately -10 to 50°C (14 to 122°F). Hot means approximately 50 to 100°C (122 to 212°F). If the resistance is not as specified, replace the camshaft position sensor.
- Measure the resistance according to the value(s) in the table below.