Precaution [08/2015 - ]
- PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL NOTE:
When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following systems after the cable is reconnected.
System Name See Procedure Power Door Lock Control System Refer to INITIALIZATION [08/2015 - ] - PRECAUTIONS WHEN USING TECHSTREAM
- When using the Techstream with the power switch off to troubleshoot: Connect the Techstream to the vehicle, and turn a courtesy light switch on and off at 1.5 second or less intervals until communication between the Techstream and vehicle begins.
- After all DTCs are cleared, check if the trouble occurs again 6 seconds after turning the power switch on (IG).
- POWER WINDOW CONTROL SYSTEM PRECAUTIONS WARNING:
- The power window control system uses a LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ] . Troubleshoot the power window control system after confirming that the communication system is functioning properly.
- The power window control system prohibits the auto up and down function if the jam protection function malfunctions.
- The power window control system prohibits the auto up and down function if the catch protection function malfunctions.
- If the power window regulator motor assembly has been replaced with a new one, initialize the power window control system.
- If the power window regulator motor assembly and door window regulator sub-assembly have been removed and installed, or if the power window regulator motor assembly was reused when a door glass or door glass run was replaced, initialize the power window control system.
- The jam protection function and the catch protection may operate unexpectedly even when the power window control system is normal due to detection of a value different from the operation learned value when the door glass moving speed changes sharply under any of the following conditions:
- A power window is being opened or closed while the vehicle is driven on a rough road.
- A power window is being opened or closed while the door is being opened or closed.
- The voltage changes abruptly.
NOTE:Do not disconnect the auxiliary battery while the power switch is on (IG). Otherwise, DTC B2313 will be stored.