Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| Monitor runs whenever following DTCs are not present | P0115, P0117, P0118 (Engine Coolant Temperature Sensor) P0102, P0103 (Mass Air Flow Sensor) |
After engine stop:
TYPICAL ENABLING CONDITIONS
| Time after engine start | 10 seconds or more |
| Battery voltage | 10.5V or more |
| ECT sensor circuit | OK |
| ECT before engine stop | 70°C (158°F) or more |
| Time that MAF is low before engine stop | 70 minutes |
| Accumulated MAF amount before engine stop | 1, 893 g or more |
| Key-off duration | 30 minutes |
After cold engine start:
TYPICAL ENABLING CONDITIONS
| Key-off duration | 5 hours |
| Time after engine start | 10 seconds or more |
| ECT sensor circuit | OK |
| ECT | 70°C (158°F) or more |
| Accumulated MAF amount | 1, 893 g or more |
| Either of the following conditions 1 or 2 is met: | - |
| 1. Duration while engine load is low | 120 seconds or more |
| 2. Duration while engine load is high | 10 seconds or more |