Inspection Procedure
- CHECK WIRE HARNESS (DLC3 - ECM AND BODY GROUND)
- Disconnect the A9 ECM connector.
- Measure the resistance of the wire harness side connectors.
Standard resistance
for 2GR-FE
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition E13-13 (TC) - A9-16 (TC) Below 1 Ω E13-4 (CG) - Body ground for 2AR-FE
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition E13-13 (TC) - A9-7 (TC) Below 1 Ω E13-4 (CG) - Body ground NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: REPLACE ECM