Unlock Sensor Check
WARNING: This page is about a different car, the 2007 Nissan Versa. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK UNLOCK SENSOR INPUT SIGNAL
Check voltage between Intelligent Key unit connector and ground.
CONNECTOR TERMINAL VOLTAGE SPECIFICATIONSTerminals Front door lock (driver side) condition Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M52 28 Ground Locked 5 Unlocked 0 OK or NG
OK >> Unlock sensor circuit is OK.
NG >> GO TO 2.
- CHECK UNLOCK SENSOR CIRCUIT
- Turn ignition switch OFF.
- Disconnect Intelligent Key unit and front door lock actuator LH (door unlock sensor) connector.
- Check continuity between Intelligent Key unit connector (A) terminal 28 and front door lock actuator LH (door unlock sensor) connector (B) terminal 4.CONNECTOR TERMINAL CONTINUITY SPECIFICATIONS
A B Continuity Intelligent Key unit connector Terminal Front door lock actuator LH (door unlock sensor) connector Terminal M52 28 D3 4 Yes - Check continuity between Intelligent Key unit connector and ground.CONNECTOR TERMINAL CONTINUITY SPECIFICATIONS
A Ground Continuity Intelligent Key unit connector Terminal M52 28 No
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between Intelligent Key unit and front door lock actuator LH (door unlock sensor).
- CHECK UNLOCK SENSOR OPERATION
Check unlock sensor.
CONNECTOR TERMINAL CONTINUITY SPECIFICATIONSTerminal Driver side door condition Continuity Unlock sensor 4 5 Lock No Unlock Yes OK or NG
OK >> GO TO 4.
NG >> Replace unlock sensor.
- CHECK UNLOCK SENSOR GROUND CIRCUIT
Check continuity between front door lock actuator LH (door unlock sensor) connector and ground.
CONNECTOR TERMINAL CONTINUITY SPECIFICATIONSFront door lock actuator LH (door unlock sensor) connector Terminal Ground Continuity D3 5 Yes OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
- CHECK INTELLIGENT KEY UNIT OUTPUT SIGNAL
- Connect Intelligent Key unit harness connector.
- Check voltage between Intelligent Key unit connector and ground.CONNECTOR TERMINAL VOLTAGE SPECIFICATIONS
Terminals Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M52 28 Ground 5
OK or NG
OK >> Replace front door lock actuator LH (door unlock sensor). Refer to "REMOVAL AND INSTALLATION ".
NG >> Replace Intelligent Key unit. Refer to "REMOVAL AND INSTALLATION OF INTELLIGENT KEY UNIT ".