Work Flow
Before performing the work flow, carry out preliminary check. Refer to "PRELIMINARY CHECK ".
- CHECK FUNCTION OF INTELLIGENT KEY SYSTEM
Check if the function related to Intelligent Key system operates normally.
All functions of Intelligent Key system do not operate >> GO TO "ALL FUNCTIONS OF INTELLIGENT KEY SYSTEM DO NOT OPERATE ".
Specific function of Intelligent Key system does not operate >> GO TO 2.
- CHECK POWER DOOR LOCK OPERATION
Check if door lock/unlock function operates with door lock and unlock switch.
OK or NG
OK >> GO TO 3.
NG >> GO TO "POWER DOOR LOCK SYSTEM ".
- CHECK DOOR REQUEST SWITCH OPERATION
Check if door lock/unlock function operates with request switch.
OK or NG
OK >> GO TO 4.
NG >> GO TO "DOOR LOCK/UNLOCK FUNCTION MALFUNCTION ".
- CHECK REMOTE KEYLESS FUNCTION
Check if the following function responds with Intelligent Key button.
- Door lock/unlock function
- Panic alarm function
OK or NG
OK >> GO TO 5.
NG >> GO TO "REMOTE KEYLESS ENTRY FUNCTION MALFUNCTION ".
- CHECK HAZARD AND BUZZER REMINDER FUNCTION
Check if hazard and buzzer reminder function responds with the following switches.
- Door request switch
- Intelligent Key button
OK or NG
OK >> GO TO 6.
NG >> GO TO "HAZARD AND BUZZER REMINDER FUNCTION MALFUNCTION ".
- CHECK WARNING CHIME FUNCTION
Check if warning chime function operates normally according to system description. Refer to "WARNING CHIME/BUZZER/LAMPS FUNCTION ".
OK or NG
OK >> GO TO 7.
NG >> GO TO "WARNING CHIME/BUZZER FUNCTION MALFUNCTION ".
- CHECK WARNING LAMP FUNCTION
Check if warning lamp could be turn on normally according to system description. Refer to "WARNING CHIME/BUZZER/LAMPS FUNCTION ".
OK or NG
OK >> End of inspection.
NG >> GO TO "WARNING LAMP FUNCTION MALFUNCTION ".