Knock Sensor: Installation
- INSTALL KNOCK SENSOR
- Install the 2 sensors with the 2 nuts as shown in the illustration.
Torque: 20 N*m (204 kgf*cm, 15 ft.*lbf)
- Connect the 2 sensor connectors.
- Install the 2 sensors with the 2 nuts as shown in the illustration.
- INSTALL NO. 4 AIR INJECTION SYSTEM HOSE
- INSTALL WATER BYPASS PIPE SUB-ASSEMBLY (See INSTALLATION )
- INSTALL INTAKE MANIFOLD ASSEMBLY
- Install the intake manifold (see INSTALLATION ).
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE: Some systems need to be initialized after the cable is reconnected (see INITIALIZATION ).