Heated Oxygen Sensor: Installation
- INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
- Using SST, install the sensor.
Torque:
without SST
44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST
40 N*m (408 kgf*cm, 30 ft.*lbf)
HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (see PRECAUTION ).
- Make sure SST and wrench are connected in a straight line.
- Using SST, install the sensor.
- INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
- Using SST, install the sensor.
Torque:
without SST
44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST
40 N*m (408 kgf*cm, 30 ft.*lbf)
HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (see PRECAUTION ).
- Make sure SST and wrench are connected in a straight line.
- Using SST, install the sensor.
- INSTALL FRONT EXHAUST PIPE ASSEMBLY (see INSTALLATION )
- INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY (except Regular Cab Standard Deck) (see INSTALLATION )
- INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY (for Regular Cab Standard Deck) (see INSTALLATION )
- INSTALL FRONT NO. 3 EXHAUST PIPE SUB-ASSEMBLY (for Regular Cab Standard Deck) (see INSTALLATION )
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE: Some systems need to be initialized after the cable is reconnected (see INITIALIZATION ).