Inspection Procedure
- INSPECT RELAY (ST Relay)
- Remove the starter relay.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
NG: REPLACE RELAY
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : Go to Next Step
- CHECK HARNESS AND CONNECTOR (TVIP ECU - BODY GROUND)
- Disconnect the T3 TVIP ECU connector.
- Turn the ignition switch START.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Specified Condition SRLY (T3-21) - Body ground 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK : REPLACE TVIP ECU