GENERATOR SERVICE SPECIFICATIONS

Application Specification
Rated Output 11.5 Volts/90 Amps
Rotor Coil resistance 2.3-2.7 Ohms @ 68°F (20°C)
Slip Ring Diameter
Standard .559-.567 in. (14.2-14.4 mm)
Minimum 0.551 in. (14 mm)
Brush Exposed Length
Standard 0.413 in. (10.5 mm)
Minimum 0.177 in. (4.5 mm)
CHARGING SYSTEM SERVICE DATA (VOLTAGE REGULATOR)

Application Specification
Regulating Voltage 13.2-14.8 Volts