Refrigerant Line: Replacement
- DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
- REPLACE FAULTY TUBE OR HOSE NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
- TORQUE CONNECTIONS TO SPECIFIED TORQUE NOTE: Connections should not be torqued tighter than the specified torque.TORQUE SPECIFICATIONS
Part Tightened N.m Kgf.cm In.Lbs Condenser At Discharge Tube 5.4 55 48 Condenser At Liquid Tube 5.4 55 48 Compressor At Discharge Hose 9.8 100 87 Compressor At Suction Hose 9.8 100 87 Expansion Valve At Evaporator 3.5 36 31 - EVACUATE AIR IN REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT
Specified amount: 500 +/- 50 g (17.64 +/- 1.76 oz.)
- INSPECT FOR LEAKAGE OF REFRIGERANT
Using a gas leak detector, check for leakage of refrigerant.
- INSPECT AIR CONDITIONER OPERATION