DTC P0130: Heated Oxygen Sensor No. 1 Circuit: Notes
CAUTION:
If ECM replacement is instructed in following tests, always ensure ECM connectors and ground circuits are okay. If either are defective, repair and repeat testing to confirm ECM malfunction.
NOTE:
Heated oxygen sensor No. 1 is located on exhaust pipe in front of catalytic converter and may be referred to as bank No. 1 sensor No. 1.