Compressor Control
- Install manifold gauge set. Start and run engine at 1500 RPM. Turn A/C on. Observe system pressure. Unplug pressure switch connector. Using a DVOM, check for continuity between pressure switch terminals No. 1 and 4. See Figure.
- Continuity should not exist when low side pressure is lower than 28 psi (2.0 kg/cm2 ) or high side pressure is higher than 455 psi (32 kg/cm2 ). Continuity should exist when low side pressure is higher than 28 psi (2.0 kg/cm2 ) or high side pressure is lower than 455 psi (32 kg/cm2 ). If continuity is not as specified, replace pressure switch.