Code 31, 32/Test No. 6 - Airflow Meter Signal
CODE 31,32/TEST NO. 6-AIRFLOW METER SIGNAL TROUBLE
| Terminals | Trouble | Condition | STD Voltage |
|---|---|---|---|
| VC - E2 | No Voltage | All | 4-6V |
| VS - E2 | No Voltage | Ignition Switch ON Measuring Plate CLOSED | 3.7-4.3V |
| VS - E2 | No Voltage | Ignition Switch ON Measuring Plate OPEN | 0.2-0.5V |
| VS - E2 | No Voltage | Idling | 2.3-2.8V |
| VS - E2 | No Voltage | 3000 RPM | 0.3-1.0V |