Airflow Meter
Turn ignition off. Unplug wiring connector from air- flow meter. Note terminal identification. See Fig 2 and Fig 3. Use ohmmeter to measure resistance between specified terminals. See AIRFLOW METER RESISTANCE SPECIFICATIONS table. Replace airflow meter if not within specification.
AIRFLOW METER RESISTANCE SPECIFICATIONS
| Terminals | Ohms | |
|---|---|---|
| E2-Vc | 100-300 | |
| E2-Vb | 200-400 | |
| E1-Fc | ||
| Measuring Plate Fully Closed | No Continuity | |
| Measuring Plate Fully Open | 0 | |
| E2-Vs | ||
| Measuring Plate Fully Closed | 20-400 | |
| Measuring Plate Fully Open | 20-1000 | |
| E2-THA | ||
| -4°F (20°C) | 10,000-20,000 | |
| 32°F (0°C) | 4000-7000 | |
| 68°F (20°C) | 2000-3000 | |
| 104°F (40°C) | 900-1300 | |
| 140°F (60°C) | 400-700 | |