Sensor - HVAC - Light/Temperature/Humidity - Remove And Replace: Installation
Installation procedure is the reverse of removal, except for the following:
CAUTION:
Do not touch the camera lens at any point during this procedure.
NOTE:
Be careful not to block the front of the camera with the HVAC light/temperature/humidity electrical harness. Route the harness around the camera lens, not in front of it.
- Clean the inside surface of the windshield with glass cleaner and make sure it is fully dry before installing the forward facing camera.
- Perform a camera pre-calibration Camera - Forward Facing (Pitch Verification) .