Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| |[Battery Charge/Discharge Current] (present value) - [Battery Charge/Discharge Current] (previous value)| | 0.003 A or less |
Time needed for diagnosis: 60 s
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.