PCV Valve: Installation
- Apply liquid gasket to the bolt threads of PCV valve, and install the PCV valve onto the cylinder block RH.NOTE: Before applying liquid gasket, degrease bolt threads of PCV valve and the mating surface of the cylinder block RH.
Liquid gasket:
THREE BOND 1217G (Part No. K0877Y0100), THREE BOND 1217H or equivalent
Tightening torque:
25 N.m (2.5 kgf-m, 18.4 ft-lb)
- Connect the PCV hose. Ref. to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (H4DOTC)>PCV Hose>INSTALLATION .