Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut ends | Less than 0.15V |
| (Fuel cut elapsed time | More than 5000 ms |
| Fuel shut-off function thereafter) | Not in operation |
| Estimated element temperature of rear oxygen sensor when fuel cut has completed | 500°C (932°F) or more |
| Compensation to rich | Rich |