Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Subaru >> 2020 >> Ascent Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Anti-Theft System - Security And Locks >> Door Lock Control System >> Inspection >> Check Power Supply And Ground Circuit Of Backup Unit

Check Power Supply And Ground Circuit Of Backup Unit

  1. CHECK FUSE AND RELAY. 
    1. Turn the ignition switch to OFF.
    2. Check the fuse on the upstream of the backup unit. Ref. to SECURITY AND LOCKS>RELAY AND FUSE>INSPECTION .

    Is the check result OK?

    Yes: Go to  2.

    No: Replace the defective fuse.

  2. CHECK POWER SUPPLY. 
    1. Disconnect the backup unit connector.
    2. Measure the voltage between backup unit connector and chassis ground.

      Connector & terminal. 

      (AD33) No. 3 (+) - Chassis ground (-):

      (AD33) No. 5 (+) - Chassis ground (-):

      (AD33) No. 8 (+) - Chassis ground (-):

    Is the voltage 9 V or more?

    Yes: Go to  3.

    No: Check the harness for open or short circuit between the backup unit and the fuse.

  3. CHECK GROUND CIRCUIT. 

    Measure the resistance between backup unit connector and chassis ground.

    Connector & terminal. 

    (AD33) No. 6 - Chassis ground:

    Is the resistance less than 10 Ω?

    Yes: The power supply and ground circuit are OK.

    No: Repair or replace the harness.