Inspection Of Switch Unit
MANUAL WIPER
- Operate the switches to check the continuity between terminals.
Preparation tool:
Circuit tester
- Front
Switch position Terminal No. Standard OFF B2 - B1 1 MΩ or more MIST B2 - B3 Less than 1 Ω LO B2 - B3 Less than 1 Ω HI B2 - B4 Less than 1 Ω Washer ON A3 - A2 Less than 1 Ω - Rear
Switch position Terminal No. Standard Washer ON (wiper interlock operation) A7 - A2
B5 - A2Less than 1 Ω OFF A7 - A2
A6 - A2
5 - A21 MΩ or more LO A6 - A2 Less than 1 Ω HI A7 - A2 Less than 1 Ω Washer ON B5 - A2 Less than 1 Ω
- Front
- Replace the switch if the inspection result is not within the standard value.