Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity L (US qt, Imp qt) Engine side Approx. 8.0 (8.5, 7.0)
Inverter assembly side Approx. 3.4 (3.6, 3.0)
Water pump Type Centrifugal impeller type
Pump characteristics Discharge rate L (US gal, Imp gal)/min 214 (56.5, 47.1) or more
Engine coolant temperature °C (°F) 80 (176)
Engine coolant concentration % 50
System pressure kPa (mAq) 88 (8.9)
Pump speed r/min 8, 580
Impeller diameter mm (in) 56 (2.20)
Number of impeller vanes pcs. 7
Pump pulley effective diameter mm (in) 100 (3.94)
Inverter water pump Motor input W 70 or less
Flow rate L (US gal, Imp gal)/min MAX 13 (3.4, 2.9) or more
Thermostat Type Wax pellet type
Starting temperature to open °C (°F) 90 - 94 (194 - 201)
Full open temperature °C (°F) 100 (212)
Valve lift mm (in) 8.0 (0.315) or more
Valve opening size mm (in) 32 (1.26)
Radiator fan Motor input W Main fan 160
Sub fan 160
Fan outer diameter mm (in) Main fan 300 (11.8)
Sub fan 300 (11.8)
Number of fan blades pcs. Main fan 9
Sub fan 11
Radiator Type Side flow, pressure type
Core dimensions mm (in) Width x Height x Thickness (649.2 x 376.2 x 27) (25.56 x 14.81 x 1.06)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 93 - 123 (0.95 - 1.25, 14 - 18)
Limit 83 (0.85, 12)
Negative pressure side Standard -1.0 4.9 or less (-0.01 0.05, -0.1 0.7)
Fin shape Corrugated fin
Water tank pipe Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 122 - 152 (1.24 - 1.55, 18 - 22)
Limit 112 (1.14, 16)
Reservoir tank Capacity L (US qt, Imp qt) 0.45 (0.48, 0.40)
Inverter tank Capacity L (US qt, Imp qt) 0.61 (0.64, 0.54)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 93 - 123 (0.95 - 1.25, 14 - 18)
Limit 83 (0.85, 12)
Negative pressure side Standard -1.0 4.9 or less (-0.01 0.05, -0.1 0.7)
  Recommended materials Item number Alternative
Engine coolant (engine side and inverter assembly side) SUBARU SUPER COOLANT (concentrated type) - -
SUBARU SUPER COOLANT (diluted type) K0670Y0001
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 -