DTC P2017: TGV Position Sensor/Switch Circuit High Bank 1: Notes
- -
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stall
- Poor driving performance
Wiring diagram:
Engine Electrical System Refer to WIRING SYSTEM (IMPREZA MODEL)>ENGINE ELECTRICAL SYSTEM>WIRING DIAGRAM . Refer to WIRING SYSTEM (CROSSTREK MODEL (EXCEPT FOR HEV))>ENGINE ELECTRICAL SYSTEM>WIRING DIAGRAM .
- check data monitor
.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Data Monitor". Refer to ENGINE (DIAGNOSTICS) (H4DO (EXCEPT FOR HEV))>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes:
Go to 2.
No:
Even if DTC is detected, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH
.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Data Monitor". Refer to ENGINE (DIAGNOSTICS) (H4DO (EXCEPT FOR HEV))>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes:
Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector.
No:
Go to 3.
- check harness between ecm and tumble generator valve actuator rh (open)
.
- Turn the ignition switch to OFF.
- Measure the resistance of harness between tumble generator valve actuator RH connector and engine ground.
Connector & terminal
(E55) No. 2 - Engine ground:
Is the resistance less than 5 Ω?
Yes:
Go to 4.
No:
Repair the harness and connector.
NOTE: In this case, repair the following item:- Open circuit in harness between ECM connector and tumble generator valve actuator RH connector
- Poor contact o (ECM connector
- check for poor contact
.
Check for poor contact of tumble generator valve actuator RH connector.
Is there poor contact of the tumble generator valve actuator RH connector?
Yes:
Repair the poor contact of tumble generator valve actuator RH connector.
No:
Replace the tumble generator valve actuator RH. Refer to FUEL INJECTION (FUEL SYSTEMS) (H4DO (EXCEPT FOR HEV))>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.