Solenoid Unit
- Remove the select lever COMPL. Ref. to CONTROL SYSTEMS>SELECT LEVER>REMOVAL .
- Remove the harness connector from the select lever COMPL.
- Remove the harness from the select lever COMPL.
- Push down the claw and remove the solenoid unit from the select lever COMPL.
- Remove the terminal of the solenoid unit using a flat tip precision screwdriver with a tip width of 1.3 mm (0.05 in) or less, KTC connector terminal tool ECC-1T or equivalent.
- Clean the tip of the solenoid unit.