Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | = 10.9 V |
| Sub feedback | In operation |
| Amount of intake air | = 10g/s(0.35oz/s) |
| Estimated temperature of the rear oxygen sensor element | = 500°C(932°F) |
| Enable conditions at interrupt control are as follows | |
| Air fuel ratio reduced from target air fuel ratio | = Value of Map |
| Continuous time when rear oxygen sensor output voltage is less than 0.5 V | = 15000ms |
VOLTAGE SPECIFICATION - MAP
| Output voltage of rear oxygen sensor (V) |
0.0 | 0.15 | 0.2 | 0.4 | 0.6 |
|---|---|---|---|---|---|
| Air fuel ratio reduced from target air fuel ratio (%) |
15 | 15 | 4 | 4 | 4 |