Execution Condition
| Secondary Parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Front oxygen (A/F) sensor closed loop control | Operation |
| Rear oxygen sensor voltage when fuel cut has completed | ≤ 0.15V |
| Fuel cut time | ≥ 5000ms |
| Estimated element temperature of rear oxygen sensor when fuel cut has completed | ≥ 500°C (932°F) |