COOLING SYSTEM SPECIFICATIONS

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity l  (US qt, Imp qt) Approx. 7.2 (7.6, 6.3)
Water pump Type Centrifugal impeller type
Discharge performance Discharge rate l  (US gal, Imp gal)/min 320 (84.5, 70.4)
Pump speed - Discharge pressure 5,500 rpm - 176.5 kPa (18 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 73.2 (2.88)
Number of impeller vanes 6
Number of pump sprocket teeth 22
Thermostat Type Wax pellet type
Starting temperature to open 80 - 84°C (176 - 183°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35(1.38)
Radiator fan Motor input Main fan W 160
Sub fan W 160
Fan diameter / Blade Main fan 320 mm (12.60 in)/5
Sub fan 320mm(12.6in)/7
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 690 x 349 x 16 (27.17 x 13.74 x 0.63)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Above: 108±14.7 (1.1±0.15, 16±2) Below: The atmospheric pressure or less
Fins Corrugated fin type
Reservoir tank Capacity l  (US qt, Imp qt) 0.45 (0.48, 0.40)
COOLING SYSTEM SPECIFICATION

A/C compressor A/C middle pressure switch Engine coolant temperature
Increase: less than 95°C (203°F)
Decrease: less than 93°C (199°F)
Increase: 95 - 101°C (203 - 214°F)
Decrease: 93 - 99°C (199 - 210°F)
Increase: More than 102°C (216°F)
Decrease: More than 100°C (212°F)
OFF 0% Refer to fig. Fig 1 100%
ON OFF Refer to fig. Fig 1 100%
ON Refer to fig. Fig 1 100%
Fig 1: Cooling System Coolant Temperature Characteristic Graph
G05018859