High Altitude Compensator Solenoids (Justy Carbureted)
- Connect ohmmeter leads between terminals of Black/White and White/Red wires of solenoid. If resistance is not 33-40 ohms, replace solenoid valve.
- Ensure windings are not grounded. Apply battery voltage to valve terminals. Ensure vacuum passage opens and closes as voltage is applied and removed.
- When solenoid is not energized, passage between "A" and "B" should be closed. See Fig 1
. When solenoid is energized, passage between "A" and "B" should be open. If solenoid valve does not operate properly, replace solenoid valve.