Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the affected ignition coil/modules.
- Ignition OFF for 90 seconds, test for less than 5 ohms between the ground circuit terminal 1 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition OFF, test for less than 5 ohms between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, verify that a test lamp illuminates between the ignition 1 voltage circuit terminal 4 and ground.
- If the test lamp does not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance.
- Exchange the affected ignition coil/module with the ignition coil/module of a good cylinder.
- Start the engine, observe the scan tool Misfire Current Cylinder parameters.
- If the misfire transfers with the suspect ignition coil/module, replace it.
- If the misfire does not transfer with the suspect ignition coil/module, replace the spark plug.