Typical Scan Tool Data
Engine Controls Ignition Relay Feedback Signal
| Display Parameters | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Ignition ON, with the engine OFF, powertrain relay commanded ON | ||||
| Engine Controls Ignition Relay Control Circuit Test Status | OK/Not Run | Short to GRD/Open | Short to GRD/Open | Short to B+ |
| Engine Controls Ignition Relay Command | ON | ON | ON | ON |
| Engine Controls Ignition Relay Feedback Signal | 12-12.9 V | 0.0 V | 0.0 V | 12-12.9 V |