Circuit/System Testing
- Ignition ON, measure for battery voltage between the CMP actuator solenoid ignition voltage and ground.
- If less than battery voltage, test the CMP actuator solenoid ignition voltage circuit for an open, short to ground.
- Connect a test lamp between the CMP actuator solenoid control circuit and a battery voltage. The test lamp should not illuminate.
- If the test lamp illuminates, test the CMP actuator solenoid control circuit for a short to voltage. If the circuit tests normal, replace the control module.
- Measure for 0 volts between the CMP actuator solenoid control and ground.
- If voltage is present, test the control circuit for a short to voltage. If the circuit tests normal, replace the control module.
- Command the CMP actuator solenoid ON. The test lamp should turn ON and OFF.
- If the test lamp does not turn ON and OFF, test the CMP actuator solenoid ignition voltage circuit for high resistance. If the circuit tests normal, replace the control module.
- If all circuits test normal, test or replace the CMP actuator solenoid.