Typical Scan Tool Data

MAF Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Engine running at various operating conditions
Parameter Normal Range:  0.5-4.3 Volts
Ignition 1 Voltage 0 Volts 0 Volts -
MAF Sensor Signal 0 Volts 0 Volts 4.5-5.0 Volts
Ground - 0 Volts -