DTC P0102 or P0103
>>
Typical Scan Tool Data
Typical Scan Tool Data
MAF Sensor
Circuit
Short to Ground
Open
Short to Voltage
Operating Conditions:
Engine running at various operating conditions
Parameter Normal Range:
0.5-4.3 Volts
Ignition 1 Voltage
0 Volts
0 Volts
-
MAF Sensor Signal
0 Volts
0 Volts
4.5-5.0 Volts
Ground
-
0 Volts
-