Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Saturn >> 2008 >> Astra XE, Standard >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Diagnostic Information and Procedures >> DTC P0616 >> Circuit/System Testing

Circuit/System Testing

  1. Ignition ON, verify DTC P0616 is set as current.
  2. Ignition OFF, disconnect the starter relay, test for 60-180 ohms between relay terminals 85 and 86.
    • If not within the specified range, replace the starter relay.
  3. Ignition ON, verify a test lamp illuminates between the relay coil supply voltage circuit terminal 86 and ground.
    • If the test lamp did not illuminate, test the relay coil supply voltage circuit for a short to ground or an open/high resistance.
  4. Ignition OFF, connect a test lamp between the relay coil supply voltage circuit terminal 86 and the relay control circuit terminal 85.
  5. Fully depress clutch pedal on manual transmissions or PARK/Neutral on automatic transmissions.
  6. Place the ignition to the start position.
  7. The test lamp should only illuminate when the ignition is held in the start position.
    • If the test lamp is always ON, test the control circuit for short to ground.
    • If the test lamp is always OFF, test the control circuit for a short to voltage or an open/ high resistance.
  8. If the circuits test normal, replace the ECM.