Circuit/System Testing
Remote Door Locks Malfunction
- Ignition OFF, disconnect the harness connector at the OnStar interface module.
- Ignition ON, test for less than 1 volt between the signal circuit terminal 3 and ground.
- If greater than the specified range, test the signal circuit for a short to voltage.
- Test for infinite resistance between the signal circuit terminal 3 and ground.
- If not the specified value, test the signal circuit for a short to ground.
- If all circuits test normal, replace the OnStar interface module.
Remote Horn Malfunction
- Ignition OFF, disconnect the harness connector at the OnStar interface module.
- Ignition ON, test for less than 1 volt between the signal circuit terminal 4 and ground.
- If greater than the specified range, test the signal circuit for a short to voltage.
- Test for infinite resistance between the signal circuit terminal 4 and ground.
- If not the specified value, test the signal circuit for a short to ground.
- If all circuits test normal, replace the OnStar interface module.