Circuit/System Testing
WARNING: This page is about a different car, the 2007 Saturn Outlook. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the harness connector X3 at the PLGM.
- Ignition OFF, test for less than 1.0 ohm of resistance between the control circuit terminal 1 and ground.
- If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If the circuits test normal, replace the PLGM.
- Ignition OFF, test for less than 1.0 ohm of resistance between the control circuit terminal 2 and ground.
- If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If the circuits test normal, replace the PLGM.
- Connect a test lamp between control circuit terminal 1 and control circuit terminal 2.
- Command the power liftgate to OPEN and CLOSE with a scan tool. The test lamp should turn ON when commanding the OPEN and CLOSE states.
- If the test lamp remains OFF during either of the commands, test for a short to ground on either control circuit. If the circuits test normal, replace the PLGM.
- If all circuits test normal, test or replace the liftgate motor assembly.