Latch Assembly Malfunction
WARNING: This page is about a different car, the 2007 Saturn Outlook. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the harness connector at the Liftgate Latch Assembly.
- Ignition OFF, test for less than 1.0 ohm of resistance between the Release control circuit terminal 1 and ground.
- If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If circuits test normal, replace the PLGM.
- Ignition OFF, test for less than 1.0 ohm of resistance between the Cinch control circuit terminal 3 and ground.
- If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If circuits test normal, replace the PLGM.
- Connect a test lamp between control circuit terminal 1 and control circuit terminal 3.
- Command the Liftgate to OPEN and CLOSE with a scan tool. The test lamp should turn ON when commanding the OPEN and CLOSE states.
- If the test lamp remains OFF during either of the commands, test for a short to ground on either control circuit. If the circuits test normal, replace the PLGM.
- Ignition OFF, test for less than 1.0 ohm of resistance between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the PLGM.
- Ignition ON, verify the scan tool Pawl Sw. parameter is INACTIVE.
- If not the specified value, test the signal circuit terminal 5 for a short to ground. If the circuit tests normal, replace the PLGM.
- Ignition ON, verify the scan tool Ratchet Sw. parameter is INACTIVE.
- If not the specified value, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the PLGM.
- Ignition ON, verify the scan tool Sector Sw. parameter is INACTIVE.
- If not the specified value, test the signal circuit terminal 4 for a short to ground. If the circuit tests normal, replace the PLGM.
- Install a 3A fused jumper wire between the signal circuit terminal 5 and low reference circuit terminal 2. Verify the scan tool Pawl Sw. parameter is ACTIVE.
- If not the specified value, test the signal circuit terminal 5 for a short to voltage or an open/high resistance. If the circuit tests normal, replace the PLGM.
- Install a 3A fused jumper wire between the signal circuit terminal 6 and low reference circuit terminal 2. Verify the scan tool Ratchet Sw. parameter is ACTIVE.
- If not the specified value, test the signal circuit terminal 6 for a short to voltage or an open/high resistance. If the circuit tests normal, replace the PLGM.
- Install a 3A fused jumper wire between the signal circuit terminal 4 and low reference circuit terminal 2. Verify the scan tool Sector Sw. parameter is ACTIVE.
- If not the specified value, test the signal circuit terminal 4 for a short to voltage or an open/high resistance. If the circuit tests normal, replace the PLGM.
- If all circuits test normal, test or replace the Liftgate Latch Assembly.