Installation Procedure
- Install the air cleaner filter into the lower air cleaner housing.
- Install the upper air cleaner cover to the lower air cleaner housing.
- Secure the air cleaner housing cover.
NOTE: Refer to Fastener Notice in Cautions and Notices.
- Connect the air cleaner resonator to the air cleaner assembly.
Tighten: Tighten the air cleaner intake duct clamp to 5 N.m (44 lb in).
- Connect the IAT sensor harness connector.