Installation Procedure
- Remove the intake air duct with resonator from the engine. Refer to Air Cleaner Resonator Outlet Duct Replacement .
- Connect one end of the gage hose (1) from the SA9127E
, to the fuel shut off and bleed assembly (5).
- Connect the other end of the gage hose (1) to the fuel pressure gage side of the gage bar set (2).
Courtesy of GENERAL MOTORS CORP.
- Remove the Schrader valve cap.
- Connect the fuel shut off and bleed assembly (5) to the Schrader valve on the fuel feed pipe (4) near the fuel rail. Use a shop towel in order to catch any remaining fuel that may leak.
- Use the scan tool, in order to pressurize the fuel system. Refer to Scan Tool Output Controls
.
- Use the drain hose (3) of the fuel shut off and bleed assembly (5) to bleed any trapped air from the lines and hoses.
- After bleeding the lines and hoses, pressurize the fuel system.
- Inspect for any fuel leaks.