Installation Procedure
- Install the heated oxygen sensor for AWD.
- Using SST
, install the heated oxygen sensor.
Tighten:
- Without SST tighten to 44 N.m (32 lb ft)
- With SST tighten to 40 N.m (30 lb ft)
- Connect the wire harness grommet.
- Connect the heated oxygen sensor connector.
- Install heated oxygen sensor for FWD.
- This torque value can be obtained by using a torque wrench with a fulcrum length of 300 mm (11.81 in.) and SST with 30 mm (1.18 in.)
- This torque value is effective when SST is parallel to the torque wrench.
- Using SST
, install the heated oxygen sensor.
Tighten:
- Without SST tighten to 44 N.m (32 lb ft)
- With SST tighten to 40 N.m (30 lb ft)
- Connect the heated oxygen sensor connector.
- Inspect for exhaust gas leaks.
NOTE:
Refer to Fastener Caution
.
IMPORTANT:
This torque value can be obtained by using a torque wrench with a fulcrum length of 300 mm (11.81 in.) and SST with 30 mm (1.18 in.). This torque value is effective when SST is parallel to the torque wrench.
IMPORTANT: