Installation Procedure
- Apply adhesive to 2 or 3 threads of the ventilation valve sub-assembly.
- Using the ball joint lock nut wrench (22 mm), install the ventilation valve sub-assembly.
Tighten:
- Without a ball joint lock nut wrench (22 mm)
20 N.m (15 lb ft)
- With a ball joint lock nut wrench (22 mm)
10 N.m (7 lb ft)
- Without a ball joint lock nut wrench (22 mm)
- Install intake manifold. Refer to Intake Manifold Replacement .
NOTE:
Refer to Fastener Caution
.