Typical Scan Tool Data: Notes
IMT Valve Position
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions: Ignition ON engine OFF. Normal range is open. | |||
| IMT Valve Ignition Voltage | Open | Open | Open |
| IMT Valve Ground | Open | Open | - |
| IMT Valve Control | Closed | Open | Open |
| IMT Valve Signal | Open | Open | Open |
IMT Valve Feedback
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions: Ignition ON engine OFF. Normal range is 18.4-25.2%. | |||
| IMT Valve Ignition Voltage | 0% | 0% | No Effect 18.4-25.2% |
| IMT Valve Ground | No Effect 18.4-25.2% |
0% | - |
| IMT Valve Control | 78-80% | 18.4-25.2% | 18.4-25.2% |
| IMT Valve Signal | 100% | 0% | 0% |