Typical Scan Tool Data
HO2S 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions: Engine operating in Closed Loop Parameter Normal Range: Fluctuates between 3.2-3.4 volts |
|||
| HO2S 1 Input | 4.99 volts* | 3.3-3.4 volts | 0.00 volts* |
| Low Reference | 4.99 volts* | 3.3-3.4 volts | 0.00 volts* |
| *Actual circuit voltage is not the same as scan tool displayed voltage | |||